Scope of the Work

Every listed wood stove has a label listing its clearances to walls and furniture and what the floor under it must be. A repair visit starts there, because stoves get moved and rooms get remodeled. Then we test the door seal, look at the baffle and firebrick, check the connector pipe joints, and replace worn parts with the maker's own. Anything that no longer matches the label is written down.

Clearances measured against the stove label
Floor protection under the stove looked at
Door seal tested and rope replaced
Baffle and firebrick looked over for damage
Connector pipe joints and screws inspected

Air Leaks Are Most Repairs

A modern wood stove is tested to burn at a set rate with its door shut and its air control set. Every part of the box that leaks air works against that. When the door rope seal goes flat, when the glass gasket has crumbled, or when a crack opens in a weld or a cast panel, the stove draws more air than it was built for. The fire runs hotter and faster than the setting asks, the stove top overheats and the wood is gone in an hour. Owners in Santa Clarita often call because a stove that once held a fire overnight now needs feeding every hour, and that change almost always traces to a seal. We check the door with a strip of paper at points around the frame, look at the glass seal and the stove body for cracks, and renew what has failed with rope and gasket sized for that model.

Inside the box, two parts take the most heat. The firebrick lining protects the steel walls, and broken or missing bricks leave the steel to warp. The baffle above the fire sends smoke and gases back through the flame so they burn rather than leaving as soot, and on many stoves it holds the secondary air tubes that make the clean burn possible. A cracked or sagging baffle means a smokier stove and a dirtier flue. We replace these parts with the ones listed for the stove, so it keeps working the way it was approved to. Stoves in Santa Clarita often sit unused through a long hot summer, and the first fires of the season are when a cracked baffle or a crumbled brick shows up. If yours has not been looked at since last winter, the start of the season is a sensible time to have it checked before you rely on it.

The Distances That Keep a Stove From Lighting the Wall

A stove radiates heat in every direction, and the rules set how far it must stand from anything that burns. A stove with a listing label carries its own clearances, often a foot or two at the back and sides, and less if the maker approved a heat shield. A stove with no label falls back on NFPA 211, which asks for thirty-six inches from walls and furniture. The single wall pipe that joins the stove to the chimney needs eighteen inches from anything that burns unless it is a listed double wall type. The floor under and in front of the stove needs a noncombustible pad sized to the label. We tape each of those distances while we are there, because a repair that restores the fire also restores the heat, and a wall that was close enough with a leaky stove may not be with a sealed one.

Where the stove connects to the chimney is the other place problems hide. A connector that leaks at its joints, a pipe that runs into a masonry flue with no thimble, or a stove that vents into an oversized old fireplace flue without a liner will all show up as smoke, creosote or a failed inspection. When we find one of these, the write-up names it and the fix that meets the rule. Repairs are priced from the visit, with each part named for your model. A wood stove that replaced an old fireplace also counts as a change of appliance under NFPA 211, which calls for a Level 2 inspection of the chimney. If yours went in without one, or before you owned the house, the visit can tell you whether the venting behind it was done to the rules, which is a question a buyer's inspector will ask.

How Bolton Chimney Company Handles the Paperwork

Rule Named First

Each finding cites NFPA 211, the listing or the local code

Permits Filed

Inserts, gas lines and rebuilds go through the city

Listed Prices

Sweeps and inspections carry a published figure

Report You Can Forward

Written for a buyer, an insurer or a city inspector

More Services

Chimney Sweep

Flue brushing that clears the buildup NFPA 211 asks owners to remove, with a written note of what came out.

Scope and rules →

Chimney Inspection

NFPA 211 Level 1 and Level 2 inspections, the level picked by what has changed at the house since the last one.

Scope and rules →

Chimney Repair

Crown, cap, mortar and flue repairs scoped to the inspection finding they clear, with a city permit filed where one applies.

Scope and rules →

Fireplace Inspection

Room-side check of firebox, damper, hearth extension and mantel distance, each measured against the clearance it has to meet.

Scope and rules →

Fireplace Repair

Firebox, damper and hearth faults fixed so the fireplace meets the lining and clearance rules it was built under.

Scope and rules →

Chimney Level 2 Inspection

The NFPA 211 inspection tied to a sale, a quake or a flue fire, with a video scan and a view of hidden sections.

Scope and rules →

Chimney Cap Installation

Stainless caps with spark arrestor screen, sized to each flue and fastened to meet the screen rules that apply near brush.

Scope and rules →

Chimney Flashing Repair

Roof-line metal renewed in step and counter layers, plus a cricket where the chimney is too wide to go without one.

Scope and rules →

Chimney Masonry Repair

Mortar joints, spalled brick and crown cracks repaired with materials that suit the original masonry.

Scope and rules →

Chimney Rebuilds

Stacks rebuilt from the point where the brick is still sound, under a city permit, with liner, crown and cap renewed on top.

Scope and rules →

Fireplace Cleaning

Firebox, doors, glass and face cleaned from the room side, which is a separate job from brushing the flue.

Scope and rules →

Gas Fireplace Cleaning

Burner, ports, glass and outside vent cap cleaned on gas units, with a carbon monoxide reading before we hand it back.

Scope and rules →

Gas Fireplace Repair

Pilot, valve, ignition and vent faults on gas units traced with a meter and fixed with parts listed for the model.

Scope and rules →

Fireplace Remodel

Facing, mantel and hearth changes drawn up around the code distances for combustible trim and hearth depth.

Scope and rules →

Fireplace Inserts

Gas and wood inserts set into the existing firebox, vented through a full-height liner and installed to the maker's listing.

Scope and rules →

Pellet Stove Repair

Pellet stoves diagnosed through their error codes and safety switches, repaired with maker's parts and checked against the vent listing.

Scope and rules →

Gas Logs

Gas log sets fitted to a wood fireplace, the vented or vent-free choice made by what the room and the local rules allow.

Scope and rules →

Chimney Seismic Retrofit

Brick chimneys braced or partly rebuilt in lighter materials to lower the chance of a stack falling through the roof in a quake.

Scope and rules →

Chimney Crown Repair

Crowns sealed or recast so they shed water past the brick face, as the standard for masonry chimneys describes.

Scope and rules →

Dryer Vent Cleaning

Dryer ducts cleared of lint from the machine to the outside hood, with the run compared against the length and material code allows.

Scope and rules →

Chimney Liner Installation

Stainless liners sized to the appliance and installed under the maker's listing, often required when an insert goes in.

Scope and rules →

Chimney Leak Repair

Water entry at the chimney traced to its source and repaired, with a written note on which part failed.

Scope and rules →

Chimney Waterproofing

Breathable water repellent put on brick after repairs, so the masonry sheds rain while it can still dry out.

Scope and rules →

Chimney Damper Repair

Throat dampers repaired or swapped for top-sealing units, so the flue opens fully for a fire and closes against weather.

Scope and rules →

Chimney Chase Cover

Stainless covers made to measure for framed chases on factory-built fireplaces, with the listed flue cap kept in place.

Scope and rules →
Call (661) 231-8464