One frame from a failed flue

The camera is a few feet above the damper. The tile walls are dark, and along one corner a hairline crack runs the full height of the tile, then carries on into the next one. Higher up, a joint between two tiles has lost its mortar and the brick behind it shows through. That frame, or one close to it, sits in most of the failed reports we are asked to fix.

Under NFPA 211 and the building code, a flue liner has to keep heat away from the framing and keep exhaust inside the flue. A crack or open joint means it does neither reliably, so the flue is marked unsafe to use until it is repaired or relined.

The flue findings and their usual fixes

These are the findings that most often fail a camera inspection, and the fix each one usually leads to.

  • Cracked or split tiles: a new stainless liner run the full height, sized to the fireplace or appliance.
  • Open or shifted joints: relining in most cases; a few short gaps near the top can sometimes be repaired on their own.
  • No liner at all: a new liner, chosen to suit the brick and the fuel.
  • A liner the wrong size after a change to gas or an insert: a new liner sized to the appliance outlet.
  • Water damage inside the flue: the source found and fixed first, usually the cap, crown or flashing, then the flue repaired.

What the rest of the chimney may need

Relining often comes with smaller items at the top and on the roof. A new liner needs a cap over it; on a wood flue in a fire hazard zone that cap carries a spark screen. Rain that got into the flue usually came through a failed crown, open flashing or a missing cricket on the high side of a wide chimney, and those need attention before the new liner goes in.

Some owners decide that rather than relining a wood fireplace, they would rather convert it to gas. A gas insert brings its own liner as part of the installation. Our fireplace inserts page covers that route.

Prices for the usual fixes

These are the jobs that come up alongside flue work and have a published price. Relining, crown work, dampers, chase covers and flashing alone are priced in writing for your chimney. The cap is quoted on site.

Camera re-check of the repaired flue
$375
Finding and stopping water that reached the flue
$535 to $3,200
Cricket to divert water off a wide stack
$425 to $965
Cricket built in with fresh flashing around the stack
$640 to $1,600
Gas insert with its own liner, in place of relining
$2,650 to $5,350
Cap over the new liner, spark screen where needed
Quoted after we measure

Each fix is listed separately in the written quote, so you can see which ones a flue repair depends on.

Flue repair questions

Can a cracked clay tile flue be patched instead of relined?

Sometimes, if the damage is limited to a few joints near the top. Cracks through tiles further down almost always mean a new liner. The camera footage decides it.

Will the new liner need a permit?

That depends on the city and the job. We check the rule for your address and note it on the quote.

Does a relined flue need another inspection?

Yes. The standard asks for a Level 2 after relining, and we film the new liner so you have the record.

Can we keep using the fireplace until the work is done?

Not if the flue is marked unsafe. Cracked tiles let heat reach wood you cannot see. Wait until the fix is in.

How do I know which liner type is right?

The fuel, the appliance, the flue size and the condition of the brick decide it. The quote names the liner type and explains the choice.

Get a written quote for the flue